An EICR records the condition of a property’s fixed electrical installation after inspection and testing. The report’s overall outcome and its observation codes set the next action, which is why the certificate label alone tells you less than the specific observations behind it. This page is for London landlords, letting agents, property managers, homeowners and businesses who need to arrange an inspection, understand what it involves, or decide what to do about an existing report.
Get EICR Price & Availability
Enter your London property details to request an EICR inspection quote and check appointment availability. Our team will review your requirements and contact you to confirm pricing and suitable dates.

Greater London
Residential and commercial properties

Starting prices from £75
Studio or one-bedroom property

Digital EICR reports
Delivered after inspection

Easy Booking
Phone, WhatsApp & online
Key Takeaways
What an EICR Covers
A London EICR records the condition of the fixed electrical installation after inspection and testing. It is not an appliance check, and it is not a guarantee against future faults.

Report Information vs Findings
This page separates general service information from the specific findings and advice in an individual report.

EICR Starting Prices and Quotes
Residential starting prices are displayed minimums; a confirmed quote comes after the property details are checked. Commercial EICRs are quoted individually once the scope is confirmed.

Understanding EICR Results and Classification Codes
The report outcome and observation codes determine the next step, and the certificate label on its own does not. An unsatisfactory report requires arranging and documenting the stated work.

England’s Five-Year EICR Inspection Requirements
Whether England's five-year inspection duty applies depends on the property and tenancy; the legal scope section points to current GOV.UK guidance rather than a single rule for every property.
Greater London EICR inspections
Clear starting prices for your property
Studio / 1 bed
£75
Starting price
2–3 bedrooms
£98.99
Starting price
4+ bedrooms
£109.99
Starting price
This service covers Greater London, residential and commercial properties, with digital EICR reports delivered after inspection. Residential starting prices run £75 for a studio or one-bedroom, £98.99 for two to three bedrooms, and £109.99 for four or more bedrooms. Treat these as minimums only.
Property size, number of circuits, access, parking, location, the congestion charge and additional consumer units all shape the confirmed price.
Commercial EICRs are quoted individually.

Request an EICR Quote
by phone, WhatsApp or online enquiry. You do not need to know a classification code or a legal rule before you ask; the team will confirm what else is needed to scope the quote.
Greater London EICR inspections
The quote that should have taken two minutes ran to twenty. A converted Victorian house in Walthamstow, four flats, three consumer units, and a prepayment meter in the basement. The single starting price we had quoted covered none of it. That call changed how we price: displayed residential starting prices by bedroom band now sit up front, and the property-specific quote comes only after we confirm the postcode, circuits, and access. We lost the clean one-number answer, and what we gained was quotes that survive first contact with the building.
The rest of this page follows that decision path: property type and reason first, then scope, inspection, and the report codes that determine what happens next. What this service actually is, who it is for, and what it delivers comes before any legal or technical detail.
EICR inspection in London: the service at a glance
The path from property type and reason to quote, inspection and action runs on one practical structure: defined reader groups, a defined inspection, and quotes that follow the property rather than a single headline figure.

On the Croydon batch-booking call, our coordinator listed the flats by postcode and bedroom count, then stopped at the fourth. A converted Victorian with a second consumer unit in the extension meant the displayed band was only a starting line. The quote had to account for the extra unit and the access arrangements. That is the lived truth behind a bedroom-band price: it opens the right conversation, and the installation closes it.

Who the service is for
The service covers residential and commercial properties across Greater London, which puts landlords, letting agents and property managers, homeowners, and businesses in the same queue. What separates them is the installation behind the door. Displayed residential prices are set by bedroom band; commercial work is quoted per property. A domestic band price covers a domestic scope, and the right figure depends on the property and its installation rather than any single advertised band.

What the service provides
An EICR is inspection and testing of the fixed electrical installation, followed by a report that records the outcome and the observations. The digital report is sent after inspection and report preparation, which keeps delivery honest rather than promising a fixed turnaround. To get a price and appointment options, readers reach the team by phone, WhatsApp or online enquiry with their property information to hand.
Before the audience pathways split, one anchor holds the rest of the page together: what an EICR actually is, and what it leaves out.
What an EICR is, and what it does not cover

Define the report in plain English
What the report is worth depends on its extent, its observations and its overall outcome. The label on the front tells you very little on its own. "Electrical safety certificate" is a shorthand that can hide more than it says: the title alone does not establish what was inspected, what was limited, or whether the document meets a particular requirement.
"Is this the certificate that proves the flat is safe?" a landlord asks, and we walk them to the extent and limitations lines, which is where the report actually answers that question.

Set clear limits on what the report tells the reader
The report covers the fixed installation as inspected. It does not cover portable appliances, and it is not a survey of the whole building. It is also not a repair quotation or a certificate for new work: if the schedule names remedial work or further investigation, that is a separate instruction priced from those observations. And it does not guarantee future condition. Read the recorded findings and recommendations, not the front-page label.

EXPERT TIP
Read an EICR as a record of the fixed installation's condition at the time of inspection, not as a certificate that every appliance, fixture or future fault is covered.
Which readers this matters for, and when, depends on the property and the reason for the report.
Who may need an EICR , and when it may be useful
The path from property type and reason to quote, inspection and action runs on one practical structure: defined reader groups, a defined inspection, and quotes that follow the property rather than a single headline figure.

Landlords of covered rented homes in England
The England regulations attach the duty to a specified rented home, which is a legal category rather than a label that follows every tenancy. For the detail of which arrangements count, the scope table and the GOV.UK guidance for the private and social rented sectors do the work. Your practical job is narrower: know the inspection due date, arrange access, retain the report, and act on the observations the report actually records.

Letting agents and property
managers
The agent’s job is to turn a portfolio into a clean set of dates and outcomes. We got the keyholder question wrong on a block of flats in Croydon. We took the address and the flat count, confirmed the date, and assumed the managing agent would meet our electrician at the intake cupboard. On the morning, nobody had the riser key.
The visit was rebooked, the tenant’s notice period ran again, and we lost half a day for a job that was otherwise ready.
The fix was simple: we now ask who holds the intake or riser key before the day, not during it, and we log that answer on the same tracker as the inspection date and report outcome. Before requesting a quote, gather the property type, occupancy and access details, and agree who arranges access and who receives the report.

Homeowners
A homeowner is not automatically on the same interval as a landlord. For an older installation, a purchase, or planned renovation work, an EICR is a practical assessment of the fixed installation's condition and suitability for continued use. When you request a quote, describe the reason and the property type, because a pre-purchase check and a renovation check can raise different questions about scope.

Businesses and commercial premises
Commercial premises do not slot into the residential bedroom-band starting prices. A shop, office or mixed-use site needs a scope-based quotation that reflects the size, use and access constraints of the actual installation.
There is no single statutory interval for commercial premises; a planned programme follows the risk assessment, usage and age of the installation.
When you enquire, provide the site address, premises type, access constraints and any known installation details, such as the consumer unit arrangement or the age of the wiring.
Before a landlord books, the scope question has to be settled, because the England duties turn on more than property type.
England landlord requirements: check the scope before booking
For the landlord reader, the legal scope decides whether the duty applies at all. In England, the duty comes from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, amended in 2025 to cover the social rented sector too. That amendment commenced in stages: some provisions took effect on 1 November 2025, others on 1 May 2026, depending on the tenancy and the provider.
Where the duty applies, the fixed electrical installation must be inspected and tested by a qualified person at least every five years. The landlord must obtain the report, then provide it to tenants and to the local council if requested.
For the landlord reader, the legal scope decides whether the duty applies at all. In England, the duty comes from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, amended in 2025 to cover the social rented sector too. That amendment commenced in stages: some provisions took effect on 1 November 2025, others on 1 May 2026, depending on the tenancy and the provider.

The phone in the booking queue rings mid-morning, an agent already halfway through listing six flats in Lewisham before we have asked for the postcode. We slow the call to two questions: are these private rented homes, and is each tenancy in England. One flat turns out to be a live-in landlord arrangement, so the duty does not touch it under the current guidance; the other five move to a fixed-price quote with the postcode and access details confirmed in writing. The five-year interval only matters once the duty actually applies.
That daily pattern is why the property label alone does not settle coverage. A flat in a converted house can be covered, excluded, or somewhere in between depending on the tenancy and the accommodation type.
Situation
What the page should explain
Practical next step
Covered private rented homes in England
Installations must be inspected and tested by a qualified person at least every five years; the landlord must obtain the report and provide it to tenants and the council if requested.
Gather the postcode, property type and access details and request a property-specific quote.
Social rented homes in England
The 2025 amendment extends the duty to the social rented sector, with commencement staged across 1 November 2025 and 1 May 2026 depending on the tenancy and provider.
Check the made 2025 instrument (2025 No. 1043) and current GOV.UK guidance for the applicable commencement date before booking.
Accommodation listed as excluded in the guidance
Shared accommodation with the landlord or their family, qualifying long leases, student halls, hostels and refuges, care homes, hospitals, hospices, certain healthcare accommodation, mobile homes, caravans and boats fall outside the England rented-sector requirements.
Confirm the exclusion against current GOV.UK guidance, and clarify the position where the accommodation type is unusual.
Owner-occupied home
The England rented-sector duty applies to tenanted homes, so an owner-occupied home does not carry the same five-year obligation.
Request a quote as a practical assessment if the age, purchase or renovation of the wiring warrants it.
Commercial premises
The residential bedroom-band starting prices do not apply; commercial premises need a scope-based quote.
Provide the premises type and access details so the team can confirm what is needed for a property-specific quote.
Where the tenancy or accommodation is unusual, the current GOV.UK guidance and the made 2025 instrument (2025 No. 1043) are the references to check rather than a blanket verdict from this page. This page is not legal advice.
Property and tenancy type
Current GOV.UK guidance and
listed exclusions
Arrange an inspection
Clarify coverage
The property label alone does not settle coverage

VISUAL SUGGESTION
Add a compact England-scope decision diagram showing property and tenancy type, then current guidance and exclusions, then the next step to arrange or clarify, so a property label alone doesn't settle coverage.
Coverage settled, the practical question shifts to what actually happens when the qualified electrician arrives.
What an EICR inspection inspection involves
The legal duty only matters if the inspection actually happens. A Lewisham landlord cancelled twice, insisting the flat was fine. When our electrician finally tested the kitchen ring, insulation resistance read 0.2 MΩ, and one socket was warm to touch.
A qualified electrician carries out a systematic visual inspection and testing of the fixed installation to BS 7671. The focus moves through the consumer unit, protective devices, circuits, sockets and lighting, earthing and bonding, and wiring condition. Each check looks for overheating, damage, deterioration, overloaded circuits, and missing or inadequate earthing and bonding.

Expert Tip
Ask whether the property is occupied and what access arrangements are possible before confirming the appointment, because access limitations can affect both the practical inspection plan and the quote.

The broad inspection and testing process

Prepare the property and occupants

Consumer unit

Protective devices

Circuits

Sockets and lighting

Earthing and bonding

VISUAL SUGGESTION
Use a labelled image or simple diagram of a domestic installation that identifies the consumer unit, circuits, sockets and lighting, earthing and bonding, and protective devices, keeping it illustrative rather than implying every component is inspected identically in every property.
The practical visit raises the natural question of duration.
How long does an EICR take?

Why duration varies

Plan the appointment
Example scenario
A landlord in Reading rings on a Tuesday, wanting one two-bedroom flat inspected before the tenancy renews on Friday. Our electrician asks where the consumer unit is, and the landlord says it is in the hall cupboard with the meter beside it. The cupboard opens easily. The loft hatch does not: it is painted shut, and the second bedroom has a sealed ceiling light. We book a two-hour window instead of the one-hour slot the landlord hoped for, and we put the access gaps in writing before the day, so the window holds.
After the visit comes the report, where each observation code tells you what to do next.
Understanding the EICR report and classification codes

The FI row is where an honest reading of a report saves a landlord real money. A client sent us a report showing FI against a note about a sealed floor void, and the old wording still sat in their head: further investigation required without delay. The A4:2026 form now says further investigation is advised. FI is advisory, like C3, and never changes the overall outcome. That plain-English distinction on a real report, not a marketing line, is the differentiator.

The report outcome

Quick guide to C1, C2, C3 and FI
Code
Plain-English meaning
What the reader should do next
C1
Danger present, risk of injury now
Act on the report's instructions without delay
C2
Potentially dangerous
Arrange the remedial work the report identifies and follow applicable requirements
C2
Improvement recommended
Note it; it is advisory and does not make the report unsatisfactory
C2
Further investigation is advised
Arrange the additional investigation if the report identifies one; it is not a confirmed defect and does not make the report unsatisfactory
An unsatisfactory outcome triggers specific next steps, and the report tells you which observations drive them.
What to do after an unsatisfactory report
An usable action sequence
Read the overall conclusion and each observation’s required action, starting from the specific wording of the report.
Identify any remedial work, further investigation, or both.
Arrange the specified work with a suitably qualified electrician. Our inspection service reports findings and does not complete remedial work.
Obtain written confirmation of completion and keep it with the EICR.
For covered rented homes, complete any required action within 28 days or the shorter period the report specifies, and provide the report to tenants and the council if requested. A council can impose a financial penalty of up to £40,000 for a breach.

Illustrative decision: a C2 observation
Consider a landlord who receives a report showing a C2 observation at a flat in Tottenham. The landlord arranges the specified remedial work with a qualified electrician, obtains written confirmation of completion, and keeps it with the EICR. What clears the observation is the completed work, evidenced in writing. This example is illustrative, not a claimed job.
An unsatisfactory outcome with required observations stays open until the work is done and documented. Written confirmation is what closes it.
Before booking a follow-up inspection or a new EICR, the cost question matters. The next section sets out London starting prices and the details that shape a property-specific quote.
Understanding the EICR report and classification codes
Price is the next question, and what shapes it. The figures on this page are starting prices, not guaranteed quotes. The final number depends on the property details you send.
The supplied residential starting prices
The page displays three residential bands as minimums. £75 covers a studio or one-bedroom property, £98.99 covers two to three bedrooms, and £109.99 covers four or more. Other London providers' 2025 guide prices sit higher: a one-bed flat typically £125 to £175, a two-to-three-bed house £175 to £250. That gap reinforces the starting-price label.
The England regulations attach the duty to a specified rented home, which is a legal category rather than a label that follows every tenancy. For the detail of which arrangements count, the scope table and the GOV.UK guidance for the private and social rented sectors do the work. Your practical job is narrower: know the inspection due date, arrange access, retain the report, and act on the observations the report actually records.

Property or service type
Studio or one-bedroom property
Starting price shown on the page
From £75
What can affect the final quote
Property size, circuits, access, parking, location, congestion charge, additional consumer units

Property or service type
Two-to-three-bedroom property
Starting price shown on the page
From £98.99
What can affect the final quote
Property size, circuits, access, parking, location, congestion charge, additional consumer units

Property or service type
Four-or-more-bedroom property
Starting price shown on the page
From £109.99
What can affect the final quote
Property size, circuits, access, parking, location, congestion charge, additional consumer units

Property or service type
Commercial EICR
Starting price shown on the page
Quote required
What can affect the final quote
Property size, circuits, access, parking, location, congestion charge, additional consumer units

What information makes a quote more useful
A useful enquiry gives the team what they need to confirm a property-specific quote: the postcode, the property type, the bedroom or floor count, occupancy, access arrangements, known circuits or consumer units, and any previous EICR. The factors that can move the final price above the starting band are property size, number of circuits, access, parking, location, the congestion charge, and additional consumer units.
£98.99 was the number a landlord in Walthamstow kept quoting to us, certain it was the whole price for his two-bedroom flat. He had counted the bedrooms twice but never once mentioned the consumer units. His converted Victorian property had two of them, and the second moved the final quote above the starting band. Bedrooms decide the band. Circuits and consumer units decide the price. We now ask for both in the first message.

Completed illustrative quote request
The example below is illustrative, not a real enquiry or a quoted outcome. A two-bedroom flat request might list: two bedrooms, one consumer unit, owner-occupied, weekday access, postcode SW16, no previous report. The displayed starting price for that band is £98.99. Send the same details and await the property-specific confirmation.

PRODUCT RECOMMENDATION
The property-details checklist beside the quote form covers postcode, property type, bedrooms or floors, occupancy, access, known circuits or consumer units, and any previous report, without treating every field as mandatory.
With a price expectation in hand, the reader can follow the booking journey.
The booking journey: from enquiry to digital report
The price you saw is a starting point. Once you have the postcode, property type and access details to hand, the steps from enquiry to report are straightforward.
The five steps
We walk each enquiry through five steps.
The five steps
We walk each enquiry through five steps.
Step 1
First, request a property-specific quote by phone, WhatsApp or online enquiry.
Step 2
Second, we confirm the scope and appointment options with you.
Step 3
Third, we arrange access for the inspection and testing.
A one-bedroom flat in Islington was the first enquiry of the week, and the landlord was sure the answer would be £75 and nothing more. Before we quoted, we asked for the postcode, how many circuits the flat had and where our electrician could park while testing. He did not know the circuit count, so he checked the cupboard by the front door and sent us a photo. It showed one consumer unit, and the only parking was a resident bay outside the building, which he could arrange for the day. We confirmed the quote in writing that afternoon, with the postcode, circuit count and parking recorded against it, so the price he booked on was the price he would pay.
Step 4
Fourth, the fixed installation is inspected and tested by a qualified electrician working to BS 7671.
Step 5
Fifth, you receive a digital EICR report after inspection.
To move forward, request a property-specific quote or book an inspection by phone, WhatsApp or online enquiry. The next section shows a concrete scene where a landlord uses this process in practice.
Landlord report handover: an illustrative scene
"Is that £142.80 actually what I pay?" a landlord in the illustration asks, and we walk him through the calculator so he can see the starting price sit inside a property-specific quote before booking.

Before the visit, this landlord confirms the inspection price, VAT and any Central London travel fee, then checks the quotation and the calculator. The scene is a draft composite illustration.

When the report lands, the classification codes set the next move: a C2 observation is marked potentially dangerous, and for a covered rented home in England the landlord must arrange the remedial work within 28 days, or any shorter period the report itself specifies.

For a private rented home in England, the report is a legal requirement before a new tenancy starts and at least every five years.
Common questions remain; answer them directly.
Frequently asked questions
After the illustrative handover scene, the practical questions are the same ones that follow every report. Here are the direct answers.
An Electrical Installation Condition Report records the condition of a property’s fixed electrical installation after inspection and testing: wiring, consumer unit or fuse board, circuits, sockets, lighting, earthing and bonding, and protective devices. It is not a blanket assessment of every portable appliance, and it does not predict future condition beyond the day of inspection.
Those answers reduce to one next step. Request a quote or speak to the team, and the closing section matches the route to your reason for an EICR.